ACR Systems OWL-500-PLASTIC 1-Channel Process Signal Data Logger

$ 190.08

Availability: 100 in stock
  • Condition: New
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Brand: ACR Systems
  • All returns accepted: Returns Accepted
  • MPN: 01-0254
  • Return shipping will be paid by: Buyer
  • Item must be returned within: 30 Days

    Description

    Subscribe to Our Newsletter
    ACR Systems OWL-500-PLASTIC Single-Channel Process Signal (4-20 mA) Data Logger with 32 KB Memory
    Brand:
    ACR Systems
    Model No:
    OWL-500-PLASTIC
    Ref No:
    01-0254
    Our Model No:
    OWL500PLASTIC
    Product Overview
    Features
    Note: OWL Data Loggers require TrendReader 2 Software to operate
    Note: Probes, transformers and transducers not included
    Connect virtually any device that has a 4-20mA output
    Record a variety of parameters (i.e. flow, level, pressure, etc.)
    Case Material: Noryl plastic
    External Connector: Removable snap type connector
    Mounting: Locking eyelet or magnetic backing
    Operating Limits: -40 to 70ºC (-40 to 158ºF)
    Clock Accuracy: +/- 2 seconds per day
    Battery: 3.6 volt Lithium
    Battery Life: 10 years under normal use (factory replaceable)
    Memory Size: 32 KB (32,767 readings)
    Sampling Methods:
    Delayed start or trigger start:
    Continuous (First-in, First-out – not available with sample rates faster than 8 seconds)
    Stop when full (Fill-then-stop)
    Sampling Rates: User selectable rates from 5 per second to once every 12 hours
    Resolution: 8-bit (1 part in 256)
    Communication: Optical - send/receive data from up to 1 in. between logger and interface cable (with no obstructions)
    Alarm Type: Optical - flashing red LED
    Input Range: 0 to 24 mA DC
    Input Impedance: 100 Ohm
    Accuracy: +/- 1% of full scale
    Memory Size: 32 KB
    Applications
    Monitoring pressure
    Wind speed
    Battery voltage
    Flow
    Tank levels
    Description
    The ACR Systems OWL 500 (OWL-500-PLASTIC) Single-Channel Process Signal (4-20 mA) Data Logger with 32 KB Memory is rugged and versatile and records the popular 4-20mA process signal with ease and convenience. It is ideal for monitoring (through commercially available transducers) a wide variety of measurement parameters. All current process signals can be converted into custom engineering units using the simple equation editor in ACR's TrendReader 2 software.
    TrendReader 2 Software
    TrendReader 2 is a powerful, versatile, and easy-to-use software package designed exclusively for ACR’s SmartReader Plus, SmartReader, IAQ, OWL, TRH, JR and Nautilus data loggers. Powerful features and easy setup enables logged data to be collected and thoroughly analyzed in seconds.
    Downloading and Communicating with the Data Logger
    Set up, download and view information from a single data logger with ACR’s IC-102 interface cable (included in software interface package). Connection is simple: plug the interface cable into the USB port of your computer and connect the other end to the logger. No tools, cards or docking stations are required.
    Setting up Data Logger
    With built-in menus for sample rate and mode, start delay, equations and more, logger setup is fast and easy. In addition, equations are already included for all ACR sensors so you need only select the appropriate equation from the menu or customize your own equation. Real-time readings are displayed in the Setup window, allowing you to verify that your logger is working correctly before placing it in the field.
    Viewing Data
    With TrendReader 2, data can be viewed in table or graphical format. For presentation purposes, view data in graphical format or for a more detailed analysis, view data in table format. Either way, multiple channels of data can be displayed at once. Multiple graphs can be displayed at once and compounded to create new graphs. For added presentation power, add comments, change graph colours, zoom in on specific portions of data, and display your data using custom engineering units. Print or copy and paste graphs into your reports and presentations. Select all or portions of the table and copy and paste into your favorite Windows program.
    Terms & Conditions
    Please note estimated delivery time above. Contact us for details or if you have a delivery requirement. We ask for your patience while striving to ensure your shipment arrives quickly and accurately.
    Domestic Shipping
    FREE Standard Shipping on items OVER and less than 30lbs to continental U.S. Add for AK, HI, or PR. Please contact us for shipping rates to any overseas US territories including: Northern Mariana Islands, Guam, Puerto Rico, U.S. Virgin Islands and American Samoa.
    PO Boxes/APOs require USPS shipping and may therefore experience longer lead times
    6.25% Sales Tax for shipping to MA
    International Shipping
    Due to international voltage requirements, please ask us prior to purchasing to confirm your product will operate correctly in your country.
    Please contact us for shipping rates to any overseas U.S. territories.
    International customers are responsible for all shipping charges, including any duties or taxes.