-40%
AEMC L261 Simple Logger II AC/DC Voltage Data Logger, 600 V
$ 213.18
- Description
- Size Guide
Description
Untitled DocumentAEMC L261 Simple Logger II AC/DC Voltage Data Logger, 600 V
Model:
L261
| Order No:
2126.05
One channel logger for voltage measuring, monitoring and troubleshooting. True RMS voltage recording up to 600V AC/DC. Stores up to 240,000 measurements.
Brand:
AEMC
Model:
L261
Order No:
2126.05
Condition:
NEW
Description
AEMC L261 Simple Logger II AC/DC Voltage Data Logger, 600 V
AEMC L261 Offers
The AEMC L261 Simple Logger II is a one channel recording device powered by an alkaline battery pack. Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency (50 or 60Hz). Harmonic measurements are calculated from these 64 samples (Harmonics are only available from the Simple Logger® II Control Panel within the DataView® software).
The Simple Logger® II records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight times per second. TRMS calculations are performed on a single line cycle. This means that the input(s) are ignored between measurement intervals.
The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.
Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instruments internal memory to the computer for analysis.
Features
TRMS voltage recording up to 600V AC/DC
64 samples per cycle
Programmable storage rates from 8 every second to 1 every day
4 user selectable storage modes
Stores up to 240,000 measurements in non-volatile memory
Powered by standard Alkaline batteries
Lightweight, compact, fits anywhere
5 LED indicators quickly and clearly display logger status
Includes FREE DataView® software for data storage, real-time display, analysis and report generation
Isolated USB 2.0 communication cable included
EN 61010-1; 300V CAT IV; 600V CAT III
Applications
Surge and Sag recording
Long term supply monitoring
Industrial, commercial, residential monitoring
Monitor voltage harmonics
Find intermittent voltage problems
Machine monitoring
Included
What's included with the AEMC L261
L261 Simple Logger II True RMS Datalogger
USB cable
DataView software
2 x 1.5V AA-cell alkaline batteries
Set of leads
Set of alligator clips
Manual
Specifications
AEMC L261 Specifications
Channels
One
Input Connection
Two recessed 4mm safety banana jacks
Measurement Range
0 to 600V AC/DC
Resolution
0.1V
Accuracy (50/60Hz)
0 to 5V: unspecified
5 to 50V: ± (0.5% of Reading + 1V)
50 to 600V: ± (0.5% of Reading + 0.5V)
Input Impedance
40MΩ
Sample Rate
64 samples/cycle
Storage Rate
Programmable from 8 every second to 1 every day
Storage Modes
Start/Stop, FIFO, Extended Recording Mode (XRM™)* and Alarm
Recording Length
15 minutes to 8 weeks, programmable using DataView®
Memory
240,000 measurements (512KB)
Data is stored in non-volatile memory and retained if the battery is low or removed
Communication
USB 2.0 optically isolated
Power Source
2 x 1.5V AA-cell Alkaline batteries (included)
Battery Life
100 hours to >45 days
(dependent on sample rate and recording length)
Terms & Conditions
Item Condition:
Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
Shipping:
We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
*Shipping Rates are for Continental US, Please Contact us for other US Destinations
Payment:
Currently all payments must be made directly though PayPal
Sales Tax:
We are required to charge sales tax in North Carolina
Return Policy:
If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.