-40%
Fluke 1730 3 Three Phase Electrical Energy Logger
$ 1845.36
- Description
- Size Guide
Description
ebay templateThe Following Items Are Included:
Fluke 1730 Three Phase Energy Logger (BC# 40493-L/T*)
(3) Fluke iFlex 1500-12 Cables
Fluke 1730 Voltage Test Lead
(2) Fluke Flexible Test Leads
(2) Short Flexible Test Leads
(4) Alligator Clips
Fluke DC Input Cable
Fluke Application Software Memory Stick
Power Cord
USB PC Interface Cable
User Manual On CD-ROM
Carrying Case w/ Strap
BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS!
Fluke 1730 Three Phase Energy Logger
Perform convenient in-the-field analysis and data checks with full graphical display
Includes Carrying Case & Accessories As Listed Above!
Working Condition: Excellent
Condition: Refurbished
Calibrated: Yes
Warranty: 1 YEAR WARRANTY
Fluke 1730 Data Logger
The new Fluke 1730 Three-Phase Electrical Energy logger introduces a new simplicity to discovering sources of electrical energy waste. Discover when and where energy in your facility is being consumed; from the service entrance to individual circuits. Profiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The new Energy Analyze software package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce the cost of your energy bill.
Load studies
Discover how much energy individual pieces of equipment are consuming when they are operating at minimum and maximum capacity. Check capacity of circuits prior to adding additional loads (various standards exist for this process; in the US the NEC 220-87 is the recommended standard). Load studies can also identify situations where you may be exceeding the allowable load on the circuit or when an agreed peak demand applies from the utility. For convenience, some load studies simply measure current which makes installation of the measuring equipment quick and easy. It is often recommended that load surveys be performed for 30 days so that all typical load conditions are encountered during the test.
Energy surveys
Users often ask where measurements should be taken for an energy survey. The answer is multiple points within the facility. Start at the main service feeders; compare the power and energy measured here with the readings from the utility meter to ensure you’re receiving the correct charges. Then move downstream to the larger loads; these should be easy to identify by the current rating of the electrical panels downstream of the service entrances. Measuring at many points will allow a full picture of energy usage across the facility to be developed. The next question users typically have is how long an energy survey should last. This of course depends on the facility, but it is recommended that you measure for a period that matches a typical facility activity period. If the facility operates over a five day work week with down time on the weekend, a seven day survey will most likely capture typical conditions. If the facility operates at a constant level for 24 hours a day, 365 days a year, a single day could be reasonably representative as long as you avoid a period where there may be planned maintenance. To capture a full picture of the facilities energy usage it is not necessarily required to have measurements made simultaneously at every consumption point in the facility. To get a comprehensive picture, spot measurements can be made and then compared on a sliding time timescale. For example, you could compare the service entrance results from a typical Tuesday between 6:00 am and 12:00 pm with those of a larger load in the facility. Typically there will be some correlation between these profiles.
Power and energy logging
When a piece of equipment is operated it instantaneously consumes a specific amount of power in watts (W) or kilowatts (kW). This power is accumulated over the operating time and expressed as energy consumed in kilowatt hours (kWh). Energy is what your electric utility charges for; there will be a standard charge from the utility per kilowatt hour. Utilities may have other additional charges, such as peak demand, which is the maximum power demand over a defined period of time, often 15 or 30 minutes. There may also be power factor charges, which are based on the effects of the inductive or capacitive loads in the facility. Optimizing peak demand and power factor often results in lower monthly electricity bills. The 1730 Three Phase Electrical Energy logger has the capability to measure and characterize these effects enabling you to analyze the results and save money.
Simplified load studies
For situations where it’s either difficult or impractical to make a voltage connection the simple load study feature allows users to perform a simplified load study by measuring current only. The user can enter the nominal expected voltage to create a simulated power study. For accurate power and energy studies it is required to monitor both voltage and current but this simplified method is useful in certain circumstances.
Features:
Key measurements:
voltage, current, power, power factor and associated values enable energy saving strategies to be implemented.
Bright, color touch screen:
Perform convenient in-the-field analysis and data checks with full graphical display.
Comprehensive logging:
all measured values are automatically logged and can be reviewed during logging and before downloading for onthe-go analysis. More than 20 separate logging sessions can be stored on the instrument
Optimized user interface:
quick, guided, graphical setup ensures you’re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty.
Complete ‘in-the-field’ setup through the front panel:
no need to return to the workshop for download and setup or to take a computer to the electrical panel.
Wide range power:
power instrument directly from the measured circuit eliminating the need to find a power outlet while allowing the instrument to be secured safely inside electrical panels.
Two USB ports:
One for PC connection and another for fast, simple download to standard USB thumb drives, or other USB devices.
Compact size:
designed to fit in tight spaces and panels
Highest safety rating in the industry:
600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream.
Optimized measurement accessories:
flat voltage cable and thin flexible current probes ensure easy installation even in tight spaces
Battery life:
four-hour operating time (backup time) per charge on lithium-ion battery.
Security:
safeguard against theft with a Kensington lock
Specifications:
Accuracy
Voltage
Range
Resolution
Intrinsic Accuracy at Reference Conditions (% of Reading + % of Full Scale)
Current: Direct input
iFlex1500-12
150 A
1500 A
0.1 A
1 A
± (1 % + 0.02 %)
± (1 % + 0.02 %)
iFlex3000-24
300 A
3000 A
1 A
10 A
± (1 % + 0.02 %)
± (1 % + 0.02 %)
iFlex6000-36
600 A
6000 A
1 A
10 A
± (1.5 % + 0.03 %)
± (1.5 % + 0.03 %)
i40s-EL clamp
4 A
40 A
1 mA
10 mA
± (0.7 % + 0.02 %)
± (0.7 % + 0.02 %)
Frequency
42.5 Hz to 69 Hz
0.01 Hz
± (0.1 %)
Aux input
± 10 V dc
0.1 mV
± (0.2 % + 0.02 %)
Voltage Min/Max
1000 V
0.1 V
± (1 % + 0.1 %)
Current Min/Max
defined by accessory
defined by accessory
± (5 % + 0.2 %)
Cosϕ/DPF
0 <= Cosϕ <=1
0.01
± 0.025
Power factor
0 <= PF <=1
0.01
± 0.025
THD on voltage
1000 %
0.1 %
± (2.5 % ± 0.05 %)
THD on current
1000 %
0.1 %
± (2.5 % ± 0.05 %)
Electrical Specifications:
Electrical specifications
Power supply
Voltage range
100 V to 500 V using safety plug input when powering from the measurement circuit
100 V to 240 V using standard power cord (IEC 60320 C7)
Power consumption
Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
Efficiency
≥ 68.2 % (in accordance with energy efficiency regulations)
Maximum no-load consumption
< 0.3 W only when powered using IEC 60320 input
Mains power frequency
50/60 Hz ± 15 %
Battery
Li-ion 3.7 V, 9.25 Wh, customer-replaceable
On-battery runtime
Four hours in standard operating mode, up to 5.5 hours in power saving mode
Charging time
< 6 hours
Data acquisition
Resolution
16-bit synchronous sampling
Sampling frequency
5120 Hz
Input signal frequency
50/60 Hz (42.5 to 69 Hz)
Circuit types
1-ϕ, 1-ϕ IT, Split phase, 3-ϕ delta, 3-ϕ wye, 3-ϕ wye IT, 3-ϕ wye balanced, 3-ϕ Aron/Blondel (2-element delta), 3-ϕ delta open leg, Currents only (load studies)
THD
THD for voltage and current is calculated using 25 harmonics
Averaging period
User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Demand interval
User selectable: 5 min, 10 min, 15 min, 20 min, 30 min
Data storage
Internal flash memory (not user replaceable)
Memory size
Typical 20 logging sessions of 10 weeks with 10-minute intervals
Logging period
Averaging period Recommended for 20 sessions Logging Period for 1 session
1 second 3 hours 2.5 days
5 seconds 15 hours 12 days
10 seconds 28 hours 24 days
30 seconds 3.5 days 10 weeks
1 minute 7 days 20 weeks
5 minutes 5 weeks 2 years
10 minutes 10 weeks > 2 years
15 minutes 3.5 months > 2 years
30 minutes 7 months > 2 years
Interfaces
USB-A
File transfer via USB flash drive, firmware updates Max. current: 120 mA
USB-mini
Data download device to PC
Extension port
Accessories
Voltage inputs
Number of inputs
4 (3 phases and neutral)
Maximum input voltage
1000 Vrms, CF 1.7
Input impedance
10 MΩ
Bandwidth (-3 dB)
2.5 kHz
Scaling
1:1, 10:1, 100:1, 1000:1 and variable
Measurement category
1000 V CAT III/600 V CAT IV
Current inputs
Number of inputs
3, mode selected automatically for attached sensor
Input voltage
Clamp input: 500 mVrms/50 mVrms; CF 2.8
Rogowski coil input
150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
Range
1 A to 150 A/10 A to 1500 A with thin iFlex flexible current probe, 12 inches
3 A to 300 A/30 A to 3000 A with thin Flex flexible current probe, 24 inches
6 A to 600 A/60 A to 6000 A with thin iFlex flexible current probe, 36 inches
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
Auxiliary inputs
Number of inputs
2
Input range
0 to ± 10 V dc, 1 reading/s
Scale factor (available 2014)
Format: kx + d user configurable
Displayed units (available 2014)
User configurable (7 characters, for example, °C, psi, or m/s)
Environmental specifications
Operating temperature
-10 °C to +50 °C (14 °F to 122 °F)
Storage temperature
-20 °C to +60 °C (−4 °F to 140 °F)
Operating humidity
10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH
30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH
40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH
Operating altitude
2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage altitude
12,000 m
Enclosure
IP50 in accordance with EN60529
Vibration
MIL 28800E, Type 3, Class III, Style B
Safety
IEC 61010-1: Overvoltage CAT IV, Measurement 1000 V CAT III/600 V CAT IV, Pollution Degree 2
EMI, RFI, EMC
EN 61326-1: Industrial
Electromagnetic compatibility
Applies to use in Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment
Radio frequency emissions
IEC CISPR 11: Group 1, Class A
Temperature coefficient
0.1 x accuracy specification/°C
General specifications
Color LCD display
4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
Dimensions
1730: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in)
Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)
1730 with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in)
Weight
1730: 1.1 kg (2.5 lb)
Power supply: 400 g (0.9 lb)
External protection
Holster, Kensington lock slot
For full Fluke 1730 product specifications, please click here:
Fluke 1730
Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our
Ebay Test Equipment Store
. All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to
contact us
for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.
Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!
We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you!
We Ship World Wide!
We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate".
Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information.
We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities.
We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed.
Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale.
Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections)
A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment.
Thank you
ALL MAJOR CREDIT CARDS & PayPal ACCEPTED
Sell Smarter with
Kyozou
.
Inventory and Ecommerce Management