  • Parameter(s) Measured: Temperature
  • Condition: Very good condition. Comes with carrying case and original components. This logger was purchased new in 2016 for a specific project and used for a very brief time before the project was discontinued. The protective plastic still covers the display screen.
  • Brand: Omega
  • Model: OM-SQ2010
  • All returns accepted: ReturnsNotAccepted

    Description

    Omega OM-SQ2010 Portable Data Logger with components, software/installation guide and protective hard carrying case. Unit was purchased New in 2016 and used only briefly for a short project that was cancelled. Included also is Aprox. 200 – 250 ft of Omega Cabling for use with Omega OM-SQ2010 Data Logger and is compatible with other devices as well. Cable is insulated 2x with fiberglass and has a deviation of 0.5 degrees F (Located in Pittsburgh, PA)
    Manufacturer Specs for the Omega OM-SQ2010 Portable Data Logger:
    No. of Analogue Channels:
    8 single ended or 4 differential inputs. The OM-SQ2010 data logger has a single analogue to digital converter (A/D) which corresponds to inputs on blocks A and B. Each connection block will accept up to 2 differential inputs or up to 4 single ended inputs (it is not possible to mix single ended and differential inputs on a block).
    Analogue Input Connections:
    Detachable srew terminal blocks
    Channel Expansion:
    No
    Universal Input:
    Yes
    Voltage Ranges (Differential and Single Ended):
    -6 to 25, -0.6 to 2.4, ±0.3V, -0.15 to 0.15, -0.075 to 0.075,
    -6 to 12, -6 to 6, -3 to 3, -0.6 to 1.2, -0.6 to 0.6
    Common Mode:
    25 V
    Current Ranges, Differential (Requires External 10 Ω Shunt):
    4 to 20 mA, ±30 mA
    Thermocouple Ranges (Differential and Single Ended):
    Type J:
    -200 to 1200°C (-328 to 2192°F)
    Type K:
    -200 to 1372°C (-328 to 2502°F)
    Type T:
    -200 to 400°C (-328 to 752°F)
    Type N:
    -200 to 1300°C (-328 to 2372°F)
    Type R:
    -50 to 1768°C (-58 to 3214°F)
    Type S:
    -50 to 1768°C (-58 to 3214°F)
    Resistance Ranges (All 2 Wire):
    0 to 1250 Ω, 0 to 5000 Ω 0 to 20,000 Ω, 0 to 300,000 Ω
    Thermistor Ranges:
    U & UU-Type:
    -50 to 150°C (-58 to 302°F),
    Y-Type:
    -50 to 150°C (-58 to 302°F)
    S-Type:
    -30 to 150°C (-22 to 302°F)
    User-Defined Thermistor:
    Enter Steinhart-Hart coefficients or RT pairs
    Pt100/1000 (2-wire):
    -200 to 850°C (-328 to 1562°F)
    A/D Resolution:
    24 bit
    Accuracy:
    See table on pdf data sheet
    Internal Reference Temperature:
    -50 to 150°C (-58 to 302°F)
    Pulse Count Ranges:
    0 to 100 Hz (1 input); 0 to 64 kHz (1 input); 0 to 16,000,000 count
    Digital State/Event Ranges:
    8 state inputs or 1 x 8 bit binary
    Digital/Alarm Outputs:
    2 open drain FETs, 18V, 0.1A
    Digital I/O Connections:
    DB25F connector
    Clock Resolution/Accuracy:
    1s/10 ppm Normal Mode - each input sampled at a max rate of 1 rdg per second
    Double-Speed (Mains Reject Off) - One input can be sampled at 10 rdgs per second and all others are sampled at a max rate of 1 rdg per second
    No of Intervals:
    4
    Data Scaling:
    Included in standard OM-SQ software
    Data Statistics:
    Calculated within OM-SQ-SOFT-PLUS software
    Calculated Channels:
    Up to 16
    Memory Internal:
    16 M (1 to 14 million readings)
    Display/Keypad:
    128 x 64 dot graphical display, 4 button keypad
    Power:
    2 C cells internal (included), or external 8 to 28 Vdc via AC adaptor and USB when plugged in
    Battery Life:
    Up to 5 days with continuous usage while sampling all channels once per second
    Sensor Power Output:
    5 V at 50 mA, external 8 to 28V at 100 mA (when connected)
    Networking:
    Via RS-232 to Ethernet adaptor (Model No. OM-SQ-NET-ADAP)
    Modem Support :
    Via RS-232 modem (GSM modem kit Model No. OM-SQ-GSM-KIT)
    PC Setup:
    Complete data logger set up possible via OM-SQ software;
    Compatible with Windows XP SP3/Vista/7 and 8 (32-bit and 64-bit)
    Front Panel Setup:
    Via 4 integral keys. All essential functionality available via key pad e.g. channel configuration, start/stop logging etc. Other advanced functions e.g. calculated channels and channel descriptions are available via connection to a PC running OM-SQ data logger software
    Stored Setups:
    6
    Operating Temperature:
    -20 to 65°C
    Dimensions:
    135 D x 175 W x 55 mm H
    Weight:
    0.7 kg
    Enclosure:
    ABS plastic