-40%
SKF-CMSS200-10-SL Machine Condition Indicator. Pack of 10. !! 00 value !!
$ 474.67
- Description
- Size Guide
Description
SKF vibration and temperature sensor CMSS-10-SL. 00 Value.The SKF Machine Condition Indicator is an economical vibration sensor and indicator for monitoring non-critical machines. It is ideal for machinery with constant operating conditions not previously monitored in plants. The device can be compared to the "check engine" light in a car. What the "check engine" light does for the car, the SKF Machine Condition Indicator does for industrial machinery. Internal sensors measure velocity, enveloped acceleration (bearing or gear impulsive vibration) and machine surface temperature.
The included magnetic read-key is used to activate the SKF Machine Condition Indicator, change operating modes, set vibration baselines and acknowledge alarms.
The unit features three LEDs to indicate the machine and bearing condition. Once the unit is illuminated, it alerts the predictive maintenance technician to do a root cause analysis on the machine. In addition, it features a barcode with serial number for machine identification purposes and easy incorporation into an Operator Driven Reliability (ODR) program, maintenance routes or scheduled check-ups.
Benefits:
Provides a simple, low cost solution to determine the basic machine health on assets not necessarily being monitored
Frees up time to concentrate on root cause analysis or maintenance instead of problem detection
Non-critical machine routes could be more widely spaced, e.g., every other month instead of monthly, with the SKF Machine Condition Indicator installed and replaced by a simple, quick check of the LEDs
Specifications:
Dimensions:
– Diameter: 33,66 mm (1.325 in.)
– Height: 68,26 mm (2.688 in.)
Form: Cone; sensor-line
Weight: 120 g (4.2 oz.)
Rating: IP 69K, for use in adverse industrial environments
Enclosure: White durable polymer cap PC/PET Blend, Bayer Makroblend UT 1018-1000 and a stainless steel base
Mounting: Stud mounted or epoxy mount
Velocity measurement: 10 Hz to 1 kHz minimum rotational speed900 r/min
Bearing measurement: Enveloped acceleration with sufficient resolution for an early Stage 3 bearing defect, speeds between 900 and 3 600 r/min
Machine surface temperature measurement range: –20 to +105 °C (–5 to +220 °F)
Alarm system: Three LEDs (multiple color)
Power source: Lithium battery 3,6 V, single use, non-replaceable
Wake up schedule: Eight times per day
Battery life: Minimum of three years (with one unacknowledged alarm)
Internal operating temperature range: –20 to +85 °C (–5 to +185 °F)