-40%
Thermocouple logger with graphic LCD screen USB-603
$ 97.68
- Description
- Size Guide
Description
Battery-powered Two-Channel Thermocouple Logger with Graphic LCD Screen, sampling frequency of 2s ~ 12hrs, multi-session recording measures and stores more than 250K readings, includes 2 type K thermocouple sensors with range from 0 to 400° CUSB data logger, autonomous, measures and stores more than 250,000 readings of 2 thermocouple inputs type J, K or T at a resolution of 0.1 ° C (2 type K thermocouple sensors are included). Using the included USB-500/600 Data Logger software, users can quickly configure the data logger and view the downloaded data with the device connection to the USB port of the PC using the provided cable.
Sampling interval
The equipment can be programmed with sampling intervals from 2 seconds to 2 hours. The recorder stores the data and then loads it to the USB media computer when the collection is complete.
Smart modes of the recorder
The user can configure the device to start recording data in any of the following ways:
Start immediately
Start when the recorder button is pressed
Start at the selected date and time
Start based on a temperature condition Alarms
It provides high alarm and low alarm options that can be configured by software. Users can also enable the alarm to be maintained so that the alarm status continues even if the registered value is no longer in an alarm condition. The maintained alarm option allows users to be notified of an alarm condition without the need to download the data from the logger. The alarms are indicated by flashing patterns of the LEDs. This device also has an LCD screen and audible alarm indicators.
Real-time LCD screen
The LCD screen can show:
Current and maximum / minimum stored temperature values
Graphic display of temperature / humidity
Registration start mode (if registration does not start immediately)
Alarm indicators
Animated icon that indicates whether the device is recording data
Lock mode indicator when the start / stop button is disabled
Multiple registration session
Users can start and stop the registration using software or using the buttons of the registrar. This feature allows storage of multiple log sessions between downloads.
Features:
2 channels, compatible with thermocouples type K, J and T
Record intervals between 2 seconds and 2 hours
Immediate start modes, delayed, when pressing button, or thrown by temperature
IP67 waterproof protection
The LCD graphic display shows real-time readings, graphs and current status
Stores more than 250000 measurements
Integrated magnets for assembly
2 type K thermocouple sensors included
Specification
Temperature
Measurement ranges
K-type thermocouple –200 °C to 1350 °C (–328 °F to 2462 °F) J-type thermocouple –200 °C to 1190 °C (–328 °F to 2174 °F)
T-type thermocouple –200 °C to 390 °C (–328 °F to 734 °F)
Internal resolution
0.1 °C (0.1 °F) typ Above 999.9 °C/°F display becomes 1 °C. Internal resolution remains at 0.1 °C/°F.
Accuracy (overall error)
±0.5 °C (±0.9 °F) typ Quoted accuracy is for the data logger only when measuring within the specified operating temperature.
Thermocouple error is not included and should also be taken into consideration.
Included Thermocouple Probes
Type
K
Measurement range
0 ºC to 400 ºC (32 ºF to 752 ºF)
Accuracy
±2.5 ºC (±4.5 ºF)
Connector type
Mini-thermocouple
Cable length
1.5 m
Stainless steel probe length
100 mm To improve response time,
the thermocouple probes supplied with the USB-603 are not electrically isolated from the thermocouple junction
Depending upon the application, it may be necessary to use electrically-isolated thermocouple probes to avoid ground loops,
and/or situations where the probes may come into contact with conductors that are at different electrical potentials
If unsure of the application needs, Measurement Computing recommends using electrically-isolated probes.
Data Sampling
Sampling intervals (software-selectable)
2 s, 5 s, 10 s, 15 s, 20 s, 30 s, 1 min, 2 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1 h, 2 h
Max temperature samples
252,928
Units
°C or °F
USB Specifications
USB device type
USB 2.0 (full speed)
Device compatibility
USB 1.1, USB 2.0
Power
Power source
Two 1/2AA 3.6 V lithium batteries
Battery life
4 months typ at 25 °C and 10 minute logging rate with no audible alarm or alarm LEDs and minimal LCD use
Environmental
Operating temperature range
–10 °C to 40 °C (–14 °F to 104 °F) Applies to the data logger module only
Refer the probe manufacturer for operating temperature of thermocouple.
Mechanical
Dimensions (L × W × H)
4.01 × 1.90 × 1.20 in. (102.0 × 48.5 × 30.5 mm)