    Description

    TR-71Ui USB Connected Temperature Data Logger with IR Connectivity
    The TR-71Ui measures and records two channels of temperature.The TR-71Ui & 72Ui are USB type data loggers that enables the downloading of recorded data by connecting directly to a PC. Also, the newly added infrared communication function can now be used to collect recorded data from the TR-71Ui/72Ui without a PC. By using a Data Collector TR-57DCi with infrared function, the collected data can be easily displayed in graph form without physically gathering the loggers, enabling the immediate on-the-spot checking of continually-changing data. Application Examples *Performance testing of humidity and heat control in housing*Managing temperature and humidity in computer server rooms*For temperature and humidity management in hospitals, museums, and temperature controlled warehouses*For humidity and temperature management in mushroom cultivation and malt rooms*Recording temperature and humidity in subways and train cars TR-71Ui TR-72Ui Measurement Channel 2 Ch 2 Ch Measurement Item Temperature Only TemperatureHumidity Internal Temperature Sensor -10 to 60 °C External Temperature Sensor -40 to 110 °C 0 to 50 °C External Humidity Sensor - 10 to 95%RH Option Sensor -60 to 155 °C (*1) -40 to 110 °C Temperature Measurement Accuracy (Standard Sensor) Average ±0.3 °C [-20 to 80 °C]Average ±0.5 °C [-40 to-20/80 to 110 °C] Average ±0.3 °C [0 to 50 °C] Humidity Measurement Accuracy (Standard Sensor) - ±5%RH [at 25 °C 50%RH] Temperature Measurement Resolution Display 0.1 °C Humidity Measurement Resolution Display - 1%RH Temperature Sensor Thermistor Humidity Sensor - Macromolecular Humidity Sensor Recording Interval 1,2,5,10,15,20,30 sec./ 1,2,5,10,15,20,30,60 min./ Total of 15 choices Logging Capacity 8,000 data sets (*2) Recording Method Endless (Overwrite from the oldest data when recording capacity is full) One time Method (Stop recording when recording capacity is full) LCD Display Measurements (Ch1 only, Ch2 only, alternating display), Recording Status,Battery Life Warning, Amount of Recorded Data, Unit of Measurement Battery AA Alkaline battery (LR6) Battery Life About 1year (*3) Communication Interfaces USB Communication / Serial Communication / Infrared Communication Infrared Communication IrPHY 1.2 low power Communication time USB Communication: about 8 secondsInfrared Communication: about 55 seconds (TR-57DCi) Dimentions H55mm x W78mm x D18mm Weight About 62g (Including AA alkaline batteries) Operating Environment for Main Unit Temperature: -10 to 60 °CHumidity: under 90%RH (without condensation) Attached Sensors TR-0106 x 2 TR-3100 x 1 (*1): There are two types of temperature sensor for TR-71Ui depending on measurement range.(*2): One data set consists of readings for all channels in that type of unit.(*3): Battery life depends upon the measuring environment, recording interval, and quality of the battery being used. When infrared communication function is enabled, battery life may be shortened if the unit is used under the inverter type fluorescent lighting.
    TR-71Ui USB Connected Temperature Data Logger with IR Connectivity
    The TR-71Ui measures and records two channels of temperature.
    The TR-71Ui & 72Ui are USB type data loggers that enables the downloading of recorded data by connecting directly to a PC. Also, the newly added infrared communication function can now be uséd to collect recorded data from the TR-71Ui/72Ui without a PC.
    By using a Data Collector TR-57DCi with infrared function, the collected data can be easily displayed in graph form without physically gathering the loggers, enabling the immediate on-the-spot checking of continually-changing data.
    Application Examples
    *Performance testing of humidity and heat control in housing
    *Managing temperature and humidity in computer server rooms
    *For temperature and humidity management in hospitals, museums, and temperature controlled warehouses
    *For humidity and temperature management in mushroom cultivation and malt rooms
    *Recording temperature and humidity in subways and train cars
    TR-71Ui
    TR-72Ui
    Measurement Channel
    2 Ch
    2 Ch
    Measurement Item
    Temperature Only
    Temperature
    Humidity
    Internal Temperature Sensor
    -10 to 60 °C
    External Temperature Sensor
    -40 to 110 °C
    0 to 50 °C
    External Humidity Sensor
    -
    10 to 95%RH
    Option Sensor
    -60 to 155 °C (*1)
    -40 to 110 °C
    Temperature Measurement Accuracy (Standard Sensor)
    Average ±0.3 °C [-20 to 80 °C]
    Average ±0.5 °C [-40 to-20/80 to 110 °C]
    Average ±0.3 °C [0 to 50 °C]
    Humidity Measurement Accuracy (Standard Sensor)
    -
    ±5%RH [at 25 °C 50%RH]
    Temperature Measurement Resolution Display
    0.1 °C
    Humidity Measurement Resolution Display
    -
    1%RH
    Temperature Sensor
    Thermistor
    Humidity Sensor
    -
    Macromolecular Humidity Sensor
    Recording Interval
    1,2,5,10,15,20,30 sec./ 1,2,5,10,15,20,30,60 min./ Total of 15 choices
    Logging Capacity
    8,000 data sets (*2)
    Recording Method
    Endless (Overwrite from the oldest data when recording capacity is full) One time Method (Stop recording when recording capacity is full)
    LCD Display
    Measurements (Ch1 only, Ch2 only, alternating display), Recording Status,Battery Life Warning, Amount of Recorded Data, Unit of Measurement
    Battery
    AA Alkaline battery (LR6)
    Battery Life
    About 1year (*3)
    Communication Interfaces
    USB Communication / Serial Communication / Infrared Communication
    Infrared Communication
    IrPHY 1.2 low power
    Communication time
    USB Communication: about 8 seconds
    Infrared Communication: about 55 seconds (TR-57DCi)
    Dimentions
    H55mm x W78mm x D18mm
    Weight
    About 62g (Including AA alkaline batteries)
    Operating Environment for Main Unit
    Temperature: -10 to 60 °C
    Humidity: under 90%RH (without condensation)
    Attached Sensors
    TR-0106 x 2
    TR-3100 x 1
    (*1): There are two types of temperature sensor for TR-71Ui depending on measurement range.
    (*2): One data set consists of readings for all channels in that type of unit.
    (*3): Battery life depends upon the measuring environment, recording interval, and quality of the battery being uséd. When infrared communication function is enabled, battery life may be shortened if the unit is uséd under the inverter type fluorescent lighting.
    ×
    Buy now and save!
    Tell a friend
    Visit store
    Watch now
    Postage info
    Click the Postage tab above the listing description for more info
    Click the Postage tab above the listing description for more info!
    Additional delivery notes
    PICK UP OPTION
    Sorry, our items are NOT available for pick-up.
    PAYING VIA PAYPAL
    We accept PayPal on our all our items so you can shop with confidence.
    Simple choose the PayPal option when proceeding through the checkout.
    Additional Information
    No additional information at this time
    Ask seller a question
    You might also like
    1236-17 Thermometer
    1236-70 Espresso Thermometer
    1246-01 Pocket Test Thermometer
    1246-02 Pocket Test Thermometer
    Contact
    To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.
    Ask seller a question
    © Tech Instrumentation
    Postage
    Click the Postage tab above the listing description for more info
    Payment
    Accepted Payment Methods
    PayPal
    Returns
    Returns are accepted
    Items must be returned within 30 days of the auction ending
    Buyer will pay for return shipping.
    eBay integration
    by