Description
TR-71wb BlueTooth & Wi-Fi Temperature Data LoggerT&D TR-71wb 2 Channel temperature measurement External thermistor temperature sensor Measuring Range: -40 to 110°C Operating Range: -10 to 60°C Accuracy: ±0.3°C Logging capacity: 8,000 data sets Measurement resolution: 0.1°C Built-in 802.11b/g/n and Bluetooth 4.2 (BLE) wireless interfaces View data on mobile devices via Thermo App WebStorage Service available Specifications TR-71wb TR-72wb TR-72wb-S Sensor (External) (*1) TR-0106 Thermistor Thermistor Polymer Resistance Platinum Resistance Electrostatic Capacitance Measurement Channels Temperature 2ch Temperature 1ch Humidity 1ch Temperature 1ch Humidity 1ch Measurement Units °C, °F °C, °F %RH °C, °F %RH Measurement Range -40 to 110 °C (Supplied Sensor) -60 to 155 °C (Optional Sensor: Fluoropolymer Coated Type) 0 to 55 °C 10 to 95 %RH -30 to 80 °C 0 to 99 %RH Accuracy Avg. ±0.3 °C [-20 to 80 °C] Avg. ±0.5 °C [-40 to -20 / 80 to 110 °C] ±0.5 °C ±5 %RH [at 25 °C, 50 %RH] ±0.3 °C [0 to 50 °C] ±0.5 °C [all other temperatures] ±2.5 %RH [at 25 °C, 10 to 85 %RH] ±4.0 %RH [at 25 °C, 0 to 10 %, 85 to 99 %RH] At temperatures other than 25 °C and 0 °C, add ±0.1 %RH per degree of difference from 25. Humidity Hysteresis: ±1.5 %RH or lower(*2) Measurement Resolution 0.1 °C 0.1 °C 1 %RH 0.1 °C 0.1 %RH Responsiveness Thermal Time Constant: Approx. 75 sec. Response Time (90%): Approx. 190 sec. Response Time (90%): Approx. 7 min. Response Time (90%): Approx. 7 min. Response Time (90%): Approx. 20 sec. LCD Display Items Measurements (fixed or alternating display), Battery Warning Mark, etc. Logging Capacity 8,000 data sets (One data set consists of readings for all channels in that type of unit.) Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. Recording Mode Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) Auto-upload Interval Select from 15 choices: OFF (No auto-upload), 1, 2, 5, 10, 15, 20, 30 min. or 1, 2, 3, 4, 6, 12, 24 hrs. Communication Interfaces Wireless LAN Communication ¥ Standard: IEEE 802.11b ¥ Security (*4) : WEP (64bit/128bit), WPA-PSK(TKIP), WPA2-PSK(AES) ¥ WPS 2.0 : Push Button Configuration ¥ Protocol: HTTP (*5) , DHCP, DNSBlueTooth Communication¥ Protocol: HTTP, DHCP, DNS Bluetooth Communication¥ Bluetooth 4.2 (Bluetooth low energy) USB Communication ¥ USB 2.0 (Mini-B connector) Power AA Alkaline Battery x 2 (AA Ni-MH batteries may also be used), USB Bus Power (5 V 200 mA) Battery Life (*5) With wireless LAN communication: Approx. 10 days to 1.5 years (Ex: Approx. 10 days when Auto-upload Interval is 1 min, 1 yr when 1 hr, 1.5 yrs when 12 hrs or more) Without wireless LAN communication: Approx. 1.5 years Dimensions H 58mm x W 78mm x D 26mm Weight Approx. 100g (including batteries) Operating Environment Temperature: -10 to 60 °C Humidity: 90 %RH or less (no condensation) Accessories Temperature Sensor (TR-0106) x 2 Temperature/Humidity Sensor (THA-3001) x 1 High Precision Temperature/Humidity Sensor (HHA-3151) x 1 AA Alkaline Battery (LR6) x 2, Registration Code Label, Manual Set (Warranty Included) *1 : With the TR-71wb, it is also possible to measure temperature with the internal sensor. However, the measurement range is restricted to the operating environment for the whole device. *2 : When used in environments where temperature and humidity are over the values of 50 °C 75 %, 60 °C 50 %, 70 °C 35 %, and 80 °C 25 %, sensor hysteresis may fluctuate by values greater than ±1.5 %RH. Under certain circumstances, it may take some time to return to normal measurement capability. *3 : The WPS feature is not available when WEP(64bit/128bit) or WPA-PSK(TKIP) is selected in Access Point Settings. If you wish to use the WPS feature, please select WPA2-PSK(AES) or disable wireless security. *4 : Optional USB Mini-B Cable US-15C is required for USB communication. *5 : Battery life varies depending upon the frequency of communication, wireless LAN environment, ambient temperature, recording interval, and battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.
TR-71wb BlueTooth & Wi-Fi Temperature Data Logger
T&D TR-71wb
2 Channel temperature measurement
External thermistor temperature sensor
Measuring Range: -40 to 110°C
Operating Range: -10 to 60°C
Accuracy: ±0.3°C
Logging capacity: 8,000 data sets
Measurement resolution: 0.1°C
Built-in 802.11b/g/n and Bluetooth 4.2 (BLE) wireless interfaces
View data on mobile devices via Thermo App
WebStorage Service available
Specifications
TR-71wb
TR-72wb
TR-72wb-S
Sensor (External)
(*1)
TR-0106
Thermistor
Thermistor
Polymer Resistance
Platinum Resistance
Electrostatic Capacitance
Measurement Channels
Temperature 2ch
Temperature 1ch
Humidity 1ch
Temperature 1ch
Humidity 1ch
Measurement Units
°C, °F
°C, °F
%RH
°C, °F
%RH
Measurement Range
-40 to 110 °C (Supplied Sensor)
-60 to 155 °C (Optional Sensor: Fluoropolymer Coated Type)
0 to 55 °C
10 to 95 %RH
-30 to 80 °C
0 to 99 %RH
Accuracy
Avg. ±0.3 °C
[-20 to 80 °C]
Avg. ±0.5 °C
[-40 to -20 / 80 to 110 °C]
±0.5 °C
±5 %RH
[at 25 °C, 50 %RH]
±0.3 °C
[0 to 50 °C]
±0.5 °C
[all other temperatures]
±2.5 %RH
[at 25 °C, 10 to 85 %RH]
±4.0 %RH
[at 25 °C, 0 to 10 %, 85 to 99 %RH]
At temperatures other than 25 °C and 0 °C, add ±0.1 %RH per degree of difference from 25. Humidity Hysteresis: ±1.5 %RH or lower
(*2)
Measurement Resolution
0.1 °C
0.1 °C
1 %RH
0.1 °C
0.1 %RH
Responsiveness
Thermal Time Constant: Approx. 75 sec.
Response Time (90%): Approx. 190 sec.
Response Time (90%): Approx. 7 min.
Response Time (90%):
Approx. 7 min.
Response Time (90%):
Approx. 20 sec.
LCD Display Items
Measurements (fixed or alternating display), Battery Warning Mark, etc.
Logging Capacity
8,000 data sets (One data set consists of readings for all channels in that type of unit.)
Recording Interval
Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode
Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full)
Auto-upload Interval
Select from 15 choices: OFF (No auto-upload), 1, 2, 5, 10, 15, 20, 30 min. or 1, 2, 3, 4, 6, 12, 24 hrs.
Communication Interfaces
Wireless LAN Communication
Â¥ Standard: IEEE 802.11b
Â¥ Security
(*4)
: WEP (64bit/128bit), WPA-PSK(TKIP), WPA2-PSK(AES)
Â¥ WPS 2.0 : Push Button Configuration
Â¥ Protocol: HTTP
(*5)
, DHCP, DNS
BlueTooth Communication
Â¥
Protocol: HTTP, DHCP, DNS Bluetooth Communication
Â¥
Bluetooth 4.2 (Bluetooth low energy)
USB Communication
Â¥ USB 2.0 (Mini-B connector)
Power
AA Alkaline Battery x 2 (AA Ni-MH batteries may also be uséd), USB Bus Power (5 V 200 mA)
Battery Life
(*5)
With wireless LAN communication: Approx. 10 days to 1.5 years (Ex: Approx. 10 days when Auto-upload Interval is 1 min, 1 yr when 1 hr, 1.5 yrs when 12 hrs or more)
Without wireless LAN communication: Approx. 1.5 years
Dimensions
H 58mm x W 78mm x D 26mm
Weight
Approx. 100g (including batteries)
Operating Environment
Temperature: -10 to 60 °C
Humidity: 90 %RH or less (no condensation)
Accessories
Temperature Sensor
(TR-0106) x 2
Temperature/Humidity Sensor
(THA-3001) x 1
High Precision Temperature/Humidity Sensor
(HHA-3151) x 1
AA Alkaline Battery (LR6) x 2, Registration Code Label, Manual Set (Warranty Included)
*1
: With the TR-71wb, it is also possible to measure temperature with the internal sensor. However, the measurement range is restricted to the operating environment for the whole device.
*2
: When uséd in environments where temperature and humidity are over the values of 50 °C 75 %, 60 °C 50 %, 70 °C 35 %, and 80 °C 25 %, sensor hysteresis may fluctuate by values greater than ±1.5 %RH. Under certain circumstances, it may take some time to return to normal measurement capability.
*3
: The WPS feature is not available when WEP(64bit/128bit) or WPA-PSK(TKIP) is selected in Access Point Settings. If you wish to use the WPS feature, please select WPA2-PSK(AES) or disable wireless security.
*4
: Optional USB Mini-B Cable US-15C is required for USB communication.
*5
: Battery life varies depending upon the frequency of communication, wireless LAN environment, ambient temperature, recording interval, and battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.
×
×
×
Buy now and save!
Tell a friend
Visit store
Watch now
Postage info
Click the Postage tab above the listing description for more info
Click the Postage tab above the listing description for more info!
Additional delivery notes
PICK UP OPTION
Sorry, our items are NOT available for pick-up.
PAYING VIA PAYPAL
We accept PayPal on our all our items so you can shop with confidence.
Simple choose the PayPal option when proceeding through the checkout.
Additional Information
No additional information at this time
Ask seller a question
You might also like
1236-17 Thermometer
1236-70 Espresso Thermometer
1246-01-1 Pocket Test Thermometer
1246-02 Pocket Test Thermometer
Contact
To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.
Ask seller a question
© Tech Instrumentation
Postage
Click the Postage tab above the listing description for more info
Payment
Accepted Payment Methods
PayPal
Returns
Returns are accepted
Items must be returned within 30 days of the auction ending
Buyer will pay for return shipping.
eBay integration
by