TR-72wb Individual Wi-Fi & Bluetooth Temperature and Humidity Data Logger

$ 155.33

Availability: 10 in stock
  • Condition: New
  • MPN: Does Not Apply
  • Item must be returned within: 30 Days
  • All returns accepted: Returns Accepted
  • Return shipping will be paid by: Buyer
  • Brand: TandD
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Restocking Fee: No

    Description

    TR-72wb Individual Wi-Fi & Bluetooth Temperature and Humidity Data Logger
    The TR-72wb is a temperature/humidity logger and it can be purchased in a high precision version, the TR-72wf-H. The TR-71wf is a temperature data logger that can monitor two temperature zones, while In addition to the basic features of T&D's standard data loggers such as battery operation and USB communication function*1, the TR-71wf/72wf supports communication with mobile devices and can be used without a PC. By using T&D WebStorage Service*2, a cloud service provided by T&D free of charge, it is possible to access stored data anytime from anywhere. *1: An optional USB communication cable (sold separately) is required. *2: To carry out the auto uploading of recorded data to T&D WebStorage Service, it is necessary to have Internet access via a wireless LAN and a T&D WebStorage Service User ID. TR-71wf TR-72wf TR-72wf-H Sensor (External) (*1) TR-0106 Thermistor Thermistor Polymer Resistance Platinum Resistance Electrostatic Capacitance Measurement Channels Temperature 2ch Temperature 1ch Humidity 1ch Temperature 1ch Humidity 1ch Measurement Units °C, °F °C, °F %RH °C, °F %RH Measurement Range -40 to 110 °C (Supplied Sensor) -60 to 155 °C (Optional Sensor: Fluoropolymer Coated Type) 0 to 55 °C 10 to 95 %RH -30 to 80 °C 0 to 99 %RH Accuracy Avg. ±0.3 °C [-20 to 80 °C] Avg. ±0.5 °C [-40 to -20 / 80 to 110 °C] ±0.5 °C ±5 %RH [at 25 °C, 50 %RH] ±0.3 °C [0 to 50 °C] ±0.5 °C [all other temperatures] ±2.5 %RH [at 25 °C, 10 to 85 %RH] ±4.0 %RH [at 25 °C, 0 to 10 %, 85 to 99 %RH] At temperatures other than 25 °C and 0 °C, add ±0.1 %RH per degree of difference from 25. Humidity Hysteresis: ±1.5 %RH or lower(*2) Measurement Resolution 0.1 °C 0.1 °C 1 %RH 0.1 °C 0.1 %RH Responsiveness Thermal Time Constant: Approx. 75 sec. Response Time (90%): Approx. 190 sec. Response Time (90%): Approx. 7 min. Response Time (90%): Approx. 7 min. Response Time (90%): Approx. 20 sec. LCD Display Items Measurements (fixed or alternating display), Battery Warning Mark, etc. Logging Capacity 8,000 data sets (One data set consists of readings for all channels in that type of unit.) Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. Recording Mode Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) Auto-upload Interval Select from 15 choices: OFF (No auto-upload), 1, 2, 5, 10, 15, 20, 30 min. or 1, 2, 3, 4, 6, 12, 24 hrs. Communication Interfaces Wireless LAN Communication ¥ Standard: IEEE 802.11b ¥ Security (*3) : WEP (64bit/128bit), WPA-PSK(TKIP), WPA2-PSK(AES) ¥ WPS 2.0 : Push Button Configuration ¥ Protocol: HTTP, DHCP, DNS USB Communication (*4) ¥ USB 2.0 (Mini-B connector) Power AA Alkaline Battery x 2 (AA Ni-MH batteries may also be used), USB Bus Power (5 V 200 mA) Battery Life (*5) With wireless LAN communication: Approx. 10 days to 1.5 years (Ex: Approx. 10 days when Auto-upload Interval is 1 min, 1 yr when 1 hr, 1.5 yrs when 12 hrs or more) Without wireless LAN communication: Approx. 1.5 years Dimensions H 58mm x W 78mm x D 26mm Weight Approx. 100g (including batteries) Operating Environment Temperature: -10 to 60 °C Humidity: 90 %RH or less (no condensation) Accessories Temperature Sensor (TR-0106) x 2 Temperature/Humidity Sensor (THA-3001) x 1 High Precision Temperature/Humidity Sensor (HHA-3151) x 1 AA Alkaline Battery (LR6) x 2, Registration Code Label, Manual Set (Warranty Included) *1 : With the TR-71wf, it is also possible to measure temperature with the internal sensor. However, the measurement range is restricted to the operating environment for the whole device. *2 : When used in environments where temperature and humidity are over the values of 50 °C 75 %, 60 °C 50 %, 70 °C 35 %, and 80 °C 25 %, sensor hysteresis may fluctuate by values greater than ±1.5 %RH. Under certain circumstances, it may take some time to return to normal measurement capability. *3 : The WPS feature is not available when WEP(64bit/128bit) or WPA-PSK(TKIP) is selected in Access Point Settings. If you wish to use the WPS feature, please select WPA2-PSK(AES) or disable wireless security. *4 : Optional USB Mini-B Cable US-15C is required for USB communication. *5 : Battery life varies depending upon the frequency of communication, wireless LAN environment, ambient temperature, recording interval, and battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.
    TR-72wb Individual Wi-Fi & Bluetooth Temperature and Humidity Data Logger
    The TR-72wb is a temperature/humidity logger and it can be purchased in a high precision version, the TR-72wf-H.  The TR-71wf is a temperature data logger that can monitor two temperature zones, while
    In addition to the basic features of T&D's standard data loggers such as battery operation and USB communication function*1, the TR-71wf/72wf supports communication with mobile devices and can be uséd without a PC.
    By using T&D WebStorage Service*2, a cloud service provided by T&D free of charge, it is possible to access stored data anytime from anywhere.
    *1: An optional USB communication cable (sold separately) is required.
    *2: To carry out the auto uploading of recorded data to T&D WebStorage Service, it is necessary to have Internet access via a wireless LAN and a T&D WebStorage Service User ID.
    TR-71wf
    TR-72wf
    TR-72wf-H
    Sensor (External)
    (*1)
    TR-0106
    Thermistor
    Thermistor
    Polymer Resistance
    Platinum Resistance
    Electrostatic Capacitance
    Measurement Channels
    Temperature 2ch
    Temperature 1ch
    Humidity 1ch
    Temperature 1ch
    Humidity 1ch
    Measurement Units
    °C, °F
    °C, °F
    %RH
    °C, °F
    %RH
    Measurement Range
    -40 to 110 °C (Supplied Sensor)
    -60 to 155 °C (Optional Sensor: Fluoropolymer Coated Type)
    0 to 55 °C
    10 to 95 %RH
    -30 to 80 °C
    0 to 99 %RH
    Accuracy
    Avg. ±0.3 °C
    [-20 to 80 °C]
    Avg. ±0.5 °C
    [-40 to -20 / 80 to 110 °C]
    ±0.5 °C
    ±5 %RH
    [at 25 °C, 50 %RH]
    ±0.3 °C
    [0 to 50 °C]
    ±0.5 °C
    [all other temperatures]
    ±2.5 %RH
    [at 25 °C, 10 to 85 %RH]
    ±4.0 %RH
    [at 25 °C, 0 to 10 %, 85 to 99 %RH]
    At temperatures other than 25 °C and 0 °C, add ±0.1 %RH per degree of difference from 25. Humidity Hysteresis: ±1.5 %RH or lower
    (*2)
    Measurement Resolution
    0.1 °C
    0.1 °C
    1 %RH
    0.1 °C
    0.1 %RH
    Responsiveness
    Thermal Time Constant: Approx. 75 sec.
    Response Time (90%): Approx. 190 sec.
    Response Time (90%): Approx. 7 min.
    Response Time (90%):
    Approx. 7 min.
    Response Time (90%):
    Approx. 20 sec.
    LCD Display Items
    Measurements (fixed or alternating display), Battery Warning Mark, etc.
    Logging Capacity
    8,000 data sets (One data set consists of readings for all channels in that type of unit.)
    Recording Interval
    Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
    Recording Mode
    Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full)
    Auto-upload Interval
    Select from 15 choices: OFF (No auto-upload), 1, 2, 5, 10, 15, 20, 30 min. or 1, 2, 3, 4, 6, 12, 24 hrs.
    Communication Interfaces
    Wireless LAN Communication
    ¥ Standard: IEEE 802.11b
    ¥ Security
    (*3)
    : WEP (64bit/128bit), WPA-PSK(TKIP), WPA2-PSK(AES)
    ¥ WPS 2.0 : Push Button Configuration
    ¥ Protocol: HTTP, DHCP, DNS
    USB Communication
    (*4)
    ¥ USB 2.0 (Mini-B connector)
    Power
    AA Alkaline Battery x 2 (AA Ni-MH batteries may also be uséd), USB Bus Power (5 V 200 mA)
    Battery Life
    (*5)
    With wireless LAN communication: Approx. 10 days to 1.5 years (Ex: Approx. 10 days when Auto-upload Interval is 1 min, 1 yr when 1 hr, 1.5 yrs when 12 hrs or more)
    Without wireless LAN communication: Approx. 1.5 years
    Dimensions
    H 58mm x W 78mm x D 26mm
    Weight
    Approx. 100g (including batteries)
    Operating Environment
    Temperature: -10 to 60 °C
    Humidity: 90 %RH or less (no condensation)
    Accessories
    Temperature Sensor
    (TR-0106) x 2
    Temperature/Humidity Sensor
    (THA-3001) x 1
    High Precision Temperature/Humidity Sensor
    (HHA-3151) x 1
    AA Alkaline Battery (LR6) x 2, Registration Code Label, Manual Set (Warranty Included)
    *1
    : With the TR-71wf, it is also possible to measure temperature with the internal sensor. However, the measurement range is restricted to the operating environment for the whole device.
    *2
    : When uséd in environments where temperature and humidity are over the values of 50 °C 75 %, 60 °C 50 %, 70 °C 35 %, and 80 °C 25 %, sensor hysteresis may fluctuate by values greater than ±1.5 %RH. Under certain circumstances, it may take some time to return to normal measurement capability.
    *3
    : The WPS feature is not available when WEP(64bit/128bit) or WPA-PSK(TKIP) is selected in Access Point Settings. If you wish to use the WPS feature, please select WPA2-PSK(AES) or disable wireless security.
    *4
    : Optional USB Mini-B Cable US-15C is required for USB communication.
    *5
    : Battery life varies depending upon the frequency of communication, wireless LAN environment, ambient temperature, recording interval, and battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.
    ×
    ×
    ×
    Buy now and save!
    Tell a friend
    Visit store
    Watch now
    Postage info
    Click the Postage tab above the listing description for more info
    Click the Postage tab above the listing description for more info!
    Additional delivery notes
    PICK UP OPTION
    Sorry, our items are NOT available for pick-up.
    PAYING VIA PAYPAL
    We accept PayPal on our all our items so you can shop with confidence.
    Simple choose the PayPal option when proceeding through the checkout.
    Additional Information
    No additional information at this time
    Ask seller a question
    You might also like
    1236-17 Thermometer
    1236-70 Espresso Thermometer
    1246-01-1 Pocket Test Thermometer
    1246-02 Pocket Test Thermometer
    Contact
    To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.
    Ask seller a question
    © Tech Instrumentation
    Postage
    Click the Postage tab above the listing description for more info
    Payment
    Accepted Payment Methods
    PayPal
    Returns
    Returns are accepted
    Items must be returned within 30 days of the auction ending
    Buyer will pay for return shipping.
    eBay integration
    by